◆ FEATURES: |
1.Autotuning PID, fuzzy PID and ON/OFF control for option. |
2.3 or 4 digit displaying |
3.Sizes: 48x96mm, 48x96mm, 72x72mm, 96x96mm |
4.Universal input: TC: K, E, J, T RTD: Pt100, Cu50 |
5.Multi-output mode for option by software: relay, SSR, SCR, PWM control output. |
6.Main output for heating; Control output can be used for cooling or AL2. |
7.Different alarm mode for option by software: Deviation alarm, Absolute value alarm, Section alarm, Power off alarm | |
 |
Input type |
Thermocouple |
K, E, J, T |
Thermo resistance |
Pt100, Cu50 |
Control typeIt can be freely converted withControl type. |
On/off control |
proportion scan 0%-3600%integral time 0-3600Sdifferential time 0-3600S |
PI control |
PID control |
Control output |
R: |
Relay: AC 250V/3A or DC 30V/3A |
S: |
SSR / logic control output |
T: |
SCR control output |
Measuring accuracy |
±0.5%F.S±1digit |
A/D conversion |
Dual integral |
Sample time |
<0.5S |
Power supply |
85-260VAC/DC(TA4), 220/110VAC(TA6,7,9), or 24VDC |
Operating condition |
0-50℃ 45-85%RH |
Display |
Two line 3 digit |
Withstand voltage strength |
AC 1500V 1minBetwen power terminal and case |
Power consumption |
<5VA |
Insulation resistance |
DC 500V>50MΩ(Between power terminal and case) |
 |
AL1:R:Relay control output S:SSR/Logic control output T:SCR control output |
OUT2/AL2:R:Relay control output S:SSR/Logic control output |
T:SCR control output N:No OUT2/AL2 |
OUT1:R:Relay control output S:SSR/Logic control output T:SCR control output |
Setting :Default:Key setting K:Thrumb switch setting |
Power:Default:TA4:90-260V Other size:110/220V |
E:24VDC 10% more or less |
Size:4:48x48mm 6:48x96mm 7:72x72mm 9:96x96mm |
TA Series of Temperature Controller | |
TA4-RSR means the controller is 48x48mm in size, Power supply 85-260VDC/AC, Main output is relay, The control output is SSR/Logic, AL1 is relay output. | |