◆ FEATURES: |
1.Can be with analogue output function |
2.Sampling rate 2.5 time/second |
3.Full range for option |
4.Display range 1999 | |
 |
Max display |
1999 (AD true value) |
Range of frequency |
40-200Hz (for AC only |
Measuring mode |
Dual slope A/D conversion |
Sampling rate |
Abt.2.5/sec |
Overflow indication |
“-1”or“1”(3 1/2); |
Polarity display |
Only “-”display |
Display |
Red LED (16.8mmH) |
Power supply |
AC 110/220V 10% more or less, 50/60 Hz |
Insulation resistance |
>100m Ohm (between the housing and the terminals) |
Insulation strength |
AC 1500 1min (between the housing and the terminals) |
Weight |
Abt. 500g |
Models |
Range |
Revolution |
Use with PT |
Accuracy |
Max. input |
DP3A-AV0.2 |
2V |
1mV |
Direct input |
0.5%F.S, 2 digit float |
10V |
DP3A-AV20 |
20V |
10mV |
Direct input |
0.5%F.S, 2 digit float |
50V |
DP3A-AV200 |
200V |
100mV |
Direct input |
0.5%F.S, 2 digit float |
500V |
DP3A-AV600 |
600V |
1V |
Direct input |
0.1%F.S, 2 digit float |
1000V |
DP3A-AV10K |
10KV |
10V |
10KV:100V |
0.5%F.S, 2 digit float |
100V |
Models |
Range |
Revolution |
Accuracy |
Max. input |
DP3A-DV0.2 |
200mV |
100uV |
0.3%F.S, 2 digit float |
10V |
DP3A-DV2 |
2V |
1mV |
0.3%F.S, 2 digit float |
50V |
DP3A-DV20 |
20V |
10mV |
0.3%F.S, 2 digit float |
500V |
DP3A-DV200 |
200V |
100mV |
0.3%F.S, 2 digit float |
750V |
Models |
Range |
Revolution |
Use with CT |
Accuracy |
Max. input |
DP3A-AA0.2 |
200mA |
100uA |
Direct input |
0.5%F.S, 2 digit float |
50mA |
DP3A-AA2 |
2A |
1mA |
Direct input |
0.5%F.S, 2 digit float |
5A |
DP3A-AA20 |
20A |
10mA |
20A:5A |
0.5%F.S, 2 digit float |
10A |
DP3A-AA200 |
200A |
100mA |
200A:5A |
0.5%F.S, 2 digit float |
10A |
DP3A-AA2000 |
2000A |
1A |
2000A:5A |
0.5%F.S, 2 digit float |
10A |
Models |
Range |
Revolution |
Accuracy |
Max. input |
DP3A-DA0.0002 |
200uA |
100nA |
0.5%F.S, 2 digit float |
10mA |
DP3A-DA0.002 |
2mA |
1uA |
0.5%F.S, 2 digit float |
100mA |
DP3A-DA0.02 |
20mA |
10uA |
0.5%F.S, 2 digit float |
500mA |
DP3A-DA0.2 |
200mA |
100uA |
0.5%F.S, 2 digit float |
1mA |
DP3A-DA2 |
2A |
1mA |
0.5%F.S, 2 digit float |
5A |
DP3A-DA20 |
20A |
10mA |
0.5%F.S, 2 digit float |
100mV |
DP3A-DA200 |
200A |
100mA |
0.5%F.S, 2 digit float |
100mV |
DP3A-DA2000 |
2000A |
1A |
0.5%F.S, 2 digit float |
100mV |
Measuring:AV:AC voltage DV:DC voltage AA:AC current DA:DC current Power supply:Default:110/220V AC 50/60 Hz E:12-30V AC/DC A:Plane Adjnst Digit display:3:3 1/2 digit display DP series of digital panel meter Size:48x96x100mm
 |
Measuring:AV:AC voltage DV:DC voltage AA:AC current DA:DC current Power supply:Default:110/220V AC 50/60 Hz E:12-30V AC/DC A:Plane Adjnst Digit display:3:3 1/2 digit display DP series of digital panel meter Size:48x96x100mm |
For example, DP3A-AV600 means it is a meter with 3 digit display, 48x96x100mm size, measuring AV600 Notes: |
1. The accuracy testing temperature 23-27 degrees, humidity 35-85%. |
2. Measuring range not listed, please mention when ordering. |
3. The fix value of CT is 5A for AC current; The fix value of PT is 100V for AC voltage; The fix value of CT is 75mV for DC current. If you need others, please mention when ordering. | |